Changes

ID

Description

SWC0074-384

Update the i4SCADA server license check, to exclude the BACnet signals from counting, if there is a valid i4BACnet license available

Update the License Manager runtime to the latest version

SWC0074-385

Improve the i4SCADA licensing library to include a counter for Clients, in the i4SCADA Server

SWC0074-564

Remove the condition to have at least one TIA Signal (Symbol) available, before importing signals to a SIMATIC TIA Device

SWC0074-601

Improve performance of the SIMATIC Connector

SWC0074-553

Add the License Viewer as a separate tool, to display license details for each feature

Fixed bugs

ID

Description

SWC0074-643

"Alarm Groups Filter" and "Alarm Types Filter" not working for "wf-alarm-state-manager"

SWC0074-571

The User Manager extension does not work, when the visualization is opened in HTTPS

SWC0074-518

The "wf-panel-1" extension is incorrectly displayed, when the visualization is opened using the Chrome browser

SWC0074-567

The Unit font size for the "wf-gauge-1" is not correctly applied at run time

SWC0074-575

The additional y-axis does not get a default value, for min and max, for the wf-historical-data-chart extension

SWC0074-597

The comma is ignored when exporting chart values to a csv, for the wf-historical-data-chart extension, leading to incorrectly formatted values

SWC0074-606

If an additional signal is inserted, after predefined signal, the fill color gets black, for the wf-historical-data-chart extension

SWC0074-619

The wf-setpoint-chart does not show the entire content, if extension's height is set to less than 400px

SWC0074-123

The [OID] parameter does not work in Lines-Definition field for the wf-chart extension

SWC0074-279

The placeholder for Replacement Signal does not function in Alarm properties "HelpCause", "HelpEffect", "HelpRepair"

SWC0074-451

The "Signal Value Factor" property does not work for the wf-value extension

SWC0074-483

The "User level" property is not displayed correctly in the User Manager extension

SWC0074-519

German translation of the "Browse TIA devices" option, in SIMATIC Connector, is not correct

SWC0074-524

An error is triggered, that prevents the call, for the wf-user-manager extension

SWC0074-525

Mismatch between the server response - request, for the wf-historical-data-chart extension

SWC0074-526

The Region configuration is not working, at design-time, for the wf-historical-data-chart extension

SWC0074-533

Logdata initialy not shown if "Series Display Type" is set to "Description" for the wf-historical-data-chart extension

SWC0074-551

The Text alignment "Center" is not working at run0time for the wf-symbolic-text extension

SWC0074-563

Modal dialogs opening are not blocked by the visibility restriction properties, for the wf-icon, wf-icon-detailed and wf-icon-primitives extensions

SWC0074-568

The "Angle" property only rotates the text and not the background, for the wf-symbolic-text extension

SWC0074-576

Automatic adjustment of the wf-historical-data-chart does not work

SWC0074-602

HTML nodes in popup get stacked when opening same page in a new tab, for the wf-watchdog extension